Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Odovtos (En línea) ; 22(1): 93-101, ene.-abr. 2020. tab
Article in English | LILACS, BBO | ID: biblio-1091509

ABSTRACT

ABSTRACT The aim of this study was to evaluate the shear bond strength (SBS) of two universal adhesives (Universal Single Bond and All Bond Universal) and a two- step self-etch adhesive system (Clearfil SE Bond) to dentine at various temperatures. Materials and Methods: One hundred and twenty dentin specimens were divided randomly to 12 groups, according to adhesive systems (Universal Single Bond and All Bond Universal, Clearfil SE Bond) and temperature ( 4ºC, 20 ºC, 36ºC, 55ºC) used. Dentin specimens were prepared (n :10, adhesives were applied, and composite cylinders were polymerized. Statistical analysis of the SBS data was performed using Two-way analysis of variance (ANOVA) and Tukey's Honestly Significant Differences post-hoc test. Results: The Clearfil SE Bond was shown to have higher SBS than the universal adhesives at all temperatures; however, there was no statistically significant difference (P>0.05). In both groups, the lowest SBS values were observed in the samples at 4°C while the highest SBS values were observed in the samples at 55°C. In this case, there was a statistically significant difference (P<0.05). Conclusions: The results suggest that the effectiveness of an adhesive may increase if it is preheated at 36°C or above before use instead of being used immediately after removal from the refrigerator or at room temperature.


RESUMEN El objetivo de este estudio fue evaluar la resistencia al cizallamiento (SBS) de dos adhesivos universales (Universal Single Bond y All Bond Universal) y un sistema de adhesivo de autograbado de dos pasos (Clearfil SE Bond) a la dentina en diferentes temperaturas. Materiales y métodos: Ciento veinte muestras de dentina se dividieron aleatoriamente en 12 grupos, de acuerdo con los sistemas adhesivos (Universal Single Bond y All Bond Universal, Clearfil SE Bond) y la temperatura (4ºC, 20ºC, 36ºC, 55ºC) utilizada. Se prepararon muestras de dentina (n: 10), se aplicaron los sistemas adhesivos y se polimerizaron los cilindros compuestos. El análisis estadístico de los datos de SBS se realizó utilizando el análisis de varianza de dos vías (ANOVA) y la prueba post-hoc de Tukey's. Resultados: El Clearfil SE Bond mostró tener un SBS más alto que los adhesivos universales en todas las temperaturas evaluadas; sin embargo, no hubo una diferencia estadísticamente significativa (P> 0.05). En todos los grupos, los valores más bajos de SBS se observaron en las muestras a 4°C, mientras que los valores de SBS más altos fueron obtenidos en las muestras a 55°C (P <0.05). Conclusiones: Los resultados sugieren que la efectividad de un adhesivo puede aumentar si se precalienta a 36°C o superior, antes de usarlo inmediatamente después de sacarlo del refrigerador o a temperatura ambiente.


Subject(s)
Dentin-Bonding Agents , Dental Cements , Shear Strength , Dentin
2.
Odovtos (En línea) ; 21(1): 67-81, Jan.-Apr. 2019. tab
Article in English | LILACS, BBO | ID: biblio-1091472

ABSTRACT

Abstract The aim of this study was to compare the efficacy of the ICDAS and the DIAGNOdent Pen in the diagnosis of occlusal caries lesions without cavitation, and for basing treatment decisions on the results obtained. Eighty permanent molar teeth that were healthy and non-cavitated or that had an initial occlusal lesion were evaluated. All teeth were investigated using DIAGNOdent Pen and ICDAS by four examiners. Histological evaluation of teeth was performed using stereomicroscopy by a histologist and different experienced dentist. For evaluation of the data, weighted kappa values (kw), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and likelihood ratio (LR+) values of the tests were calculated. The diagnostic results obtained using the DIAGNOdent Pen were found to correlate better with the results obtained from histological sections than those obtained using ICDAS. When the treatment decisions of the observers depending on the results of ICDAS, and ICDAS and DIAGNOdent Pen combination were compared with the decisions made based on histological examinations, the decisions based on ICDAS and DIAGNOdent Pen combined (kw: 0.522) were more accurate than the ones based on ICDAS (kw: 0.415) alone. In conclution, professional experience is an effective factor in diagnosing occlusal caries lesions without cavitation with ICDAS and in making treatment decisions for them. DIAGNOdent Pen is sufficient in diagnosing occlusal caries lesions without cavitation.


Resumen El objetivo de este estudio fue comparar la eficacia de ICDAS y de DIAGNOdent Pen en el diagnóstico de lesiones de caries oclusales no cavitadas. Ochenta molares permanentes sanos y no cavitados fueron utilizados. Todos los dientes fueron investigados usando DIAGNOdent Pen e ICDAS por cuatro examinadores. La evaluación histológica de los dientes se realizó mediante estereomicroscopía por un histólogo y por un dentista con previa experiencia. Los resultados diagnósticos obtenidos con el DIAGNOdent Pen se correlacionan mejor con los resultados obtenidos a partir de las secciones histológicas cuando comparados a los obtenidos utilizando ICDAS. Las decisiones basadas en el uso combinado de ICDAS y DIAGNOdent Pen (kw: 0.522) fueron más precisas que los basados en ICDAS (kw: 0.415). En conclusión, la experiencia profesional es un factor eficaz en diagnóstico de lesiones de caries oclusal sin cavitación con ICDAS y en la toma de decisiones de tratamiento. DIAGNOdent Pen es una herramienta confiable para diagnosticar lesiones de caries oclusales sin cavitación.


Subject(s)
Dental Caries/diagnosis , Dental Caries/etiology , Methods
SELECTION OF CITATIONS
SEARCH DETAIL